Los cementos de ionómero vítreo de alta viscosidad para el éxito del tratamiento restaurador atraumático / (Record no. 4313)

MARC details
000 -Encabezamiento
fixed length control field 05736nam a22002537a 4500
003 - Identificador del Número de Control
control field AR-CdUFO
005 - Fecha de Ultima Modificación
control field 20200414110736.0
008 - Elementos de Fongitud Fija--Información General
fixed length control field 170307p2016 a ||||| |||| 00| 0 s d
040 ## - Origen de la Catalogación
Agencia/entidad que catalogó originalmente la obra AR-CdUFO
Entidad que transcribió la catalogación AR-CdUFO
100 1# - Entrada Principal - Nombre Personal
9 (RLIN) 1160
Nombre Personal Brain Lascano, Laura C.
245 10 - Título propiamente dicho
Título Los cementos de ionómero vítreo de alta viscosidad para el éxito del tratamiento restaurador atraumático /
Mención de responsabilidad Laura C. Brain Lascano ; Gustavo F. Molina, dir.
260 ## - Publicación, Distribución, etc. (Pie de Imprenta)
Lugar de publicación, distribución, etc. Córdoba:
Nombre de la editorial, distribuidor, etc. Facultad de Odontología. Universidad Nacional de Córdoba,
Fecha de publicación, distribución, etc. 2016.
300 ## - Descripción Física
Extensión 205 p. ;
Otros detalles físicos il. col. ,
Dimensiones 30 cm.
502 ## - Nota de Tesis
Nota de Tesis Tesis(Doctor en Odontología)--Facultad de Odontología. Universidad Nacional de Córdoba, 2016.
505 ## - Nota de Contenido Formateada
Nota de contenido formateada Índice. Introducción. Marco teórico. Hipótesis. Objetivos. Materiales y métodos. Resultados. Discusión. Conclusiones. Referencias bibliográficas. Anexos.
520 ## - Resumen, etc.
Nota de resumen, etc. Objetivo: Evaluar mediante un estudio in vitro las propiedades: Resistencia Compresiva (RC), Resistencia Flexural (RF), Resistencia al Desgaste (RD), Rugosidad Superficial (RS), Dureza Vickers (HV) y Remineralizacion de los Tejidos Adyacentes (RTA), de diversos CIV de alta viscosidad usados en el TRA con diversos materiales de recubrimiento superficial.<br/>Materiales y Métodos: Se analizaron 5 CIV: EQUIA FIL, Fuji IX, Ketac Molar Easymix, Ionofil Molar, Vitremer, combinados con diferentes recubrimientos superficiales: G-Coat Plus, Adper Single Bond y vaselina solida. Las muestras se prepararon segun instrucciones del fabricante.<br/>La superficie expuesta del CIV se protegio con materiales de recubrimiento segun cada grupo y cada ensayo y se almacenaron en agua desionizada a 37oC. La RC y RF se midieron con una maquina universal de ensayos (Diggimes). La RD se realizo con un simulador (CFW-07 Software: version 3.XX 0899.3360 S/4). La RS fue evaluada con microscopio Laser Confocal (Olympus LEXT4000). Se midio HV con Microindentador LECO Corporation, Modelo LM-247AT. Para la RTA se utilizo el SEM (Carl Zeizz). Los resultados fueron sometidos a pruebas de ANOVA y Tukey para comparar las diferencias entre grupos.<br/>Resultados: Los valores mas altos para RC se registraron para V y KM con vaselina (95,43MPay 78,15 MPa respectivamente); para RF, V (80,75MPa) seguido de los materiales con<br/>recubrimientos superficiales G-Coat Plus y Adper Single Bond (entre 54,19 y 64,71 MPa); el menor desgaste fue el EF (0,34mg); la menor Ra fue para KM, IM, EF (0.16, 0.23 y 0.29μm respectivamente) ; la mayor HV fue para EF (110,6 HV) seguido por KM con Adper Single Bond (104,2 HV); los materiales que liberaron mayor cantidad de F y Sr fueron respectivamente: EF (media: 342,9) y KM (media: 394,5).<br/>Conclusión: El efecto del recubrimiento superficial no mostro diferencia significativa para la RC ni para la RD pero si para la RF, HV donde los valores mas altos se registraron en los grupos con proteccion. No existe un solo material que reuna las mejores propiedades para aplicarlo en TRA, pero EF y KM fueron los cementos que alcanzaron el mejor desempeno en este estudio en concordancia con los reportes de estudios clinicos recientes.<br/>Palabras Claves: cementos de ionomeros vitreo, TRA, propiedades, recubrimiento superficial.
520 ## - Resumen, etc.
Nota de resumen, etc. Objective: To assess different HVGIC and coating agents used with the ART the following properties: Compressive Strength (CS) Flexural Strength (FS), wear resistance (WR), surface roughness (SR), Vickers hardness (VH) and remineralization of adjacent tissues (RTA).<br/>Materials and Methods: EQUIA FIL, Fuji IX, Ketac Molar Easymix, Ionofil Molar, Vitremer combined with different surface coatings: G-Coat Plus, with Adper Single Bond and solid vaseline, were analyzed. Samples were produced according to manufacturer's instructions, protecting each exposed surface of the CIVs with different coating materials and stored in deionized water at 37C. The CS and FS were measured using a universal testing machine (Digimess). The WR was performed using a simulator (CFW-07 Software: version 3.XX 0899.3360 S / 4). The SR was evaluated by means of confocal laser microscopy (Olympus LEXT4000). VH was measured with Microindentator LECO Corporation, Model LM-247AT.<br/>SEM (Carl Zeiss) was used for the RTA. Results were analyzed using ANOVA and Tukey tests to<br/>compare differences between groups.<br/>Results: Highest CS values were obtained with V and KM coated with vaseline (95,43MPa and<br/>78.15 MPa respectively); For FS, V (80,75MPa) obtained the highest values followed by materials coated with G-Coat Plus and Adper Single Bond (54.19 and 64.71 MParespectively); least wear was recorded for the EF (0,34mg); Ra was lower for KM, MI, EF(0.16, 0.23 and 0.29 microns, respectively); highest VH values corresponded to EF (VH 110.6) followed by KM/Adper Single Bond (104.2 HV); the highest F and Sr release was recorded in EF (mean: 342.9) and KM (mean: 394.5).<br/>Conclusion: The effect of surface coating showed no significant difference for CS and WR although it positively affected FS and VH, where highest values were recorded in groups with coating agents. There is no one such material that achieves best properties in every variable for its application with the ART approach. However, EF and KM were likely to perform better than the other groups in this study, in agreement with recently published clinical studies.<br/>Keywords: glass ionomer cements, ART, properties, surface coating.
650 #4 - Entradas Secundarias - Términos temáticos
9 (RLIN) 8135
Tópico o nombre geográfico Materiales dentales
650 #4 - Entradas Secundarias - Términos temáticos
9 (RLIN) 6699
Tópico o nombre geográfico Cementos de ionómero vítreo
650 #4 - Entradas Secundarias - Términos temáticos
9 (RLIN) 9399
Tópico o nombre geográfico Tratamiento restaurativo atraumático dental
700 1# - Entradas Secundarias - Nombre Personal
9 (RLIN) 3994
Nombre Personal Molina, Gustavo F.
Término de relación Director de tesis
856 40 - Localización Electrónica y Acceso
Identificador Uniforme de Recurso (URI) <a href="https://rdu.unc.edu.ar/handle/11086/4862">https://rdu.unc.edu.ar/handle/11086/4862</a>
Nota pública <a href="Texto completo disponible en el Repositorio Digital de la U.N.C">Texto completo disponible en el Repositorio Digital de la U.N.C</a>
942 ## - Elementos Agregados (KOHA)
Source of classification or shelving scheme Sistema de Clasificación Black
Koha item type Tesis de Doctorado
Holdings
Estado de retiro Existencia (perdido o no perdido) Fuente de clasificación o esquema de estanterías Estado general No para préstamo Ubicación (sede de origen) Sububicacón o colección (sede poseedora del item) Fecha de adquisición o compra Préstamos Koha (veces que fue prestado) Signatura topográfica Número de inventario (código de barras) Última vez visto (Koha) Fecha del precio de reemplazo Tipo de ítem (Koha)
    Sistema de Clasificación Black     Biblioteca de la Facultad de Odontología Biblioteca de la Facultad de Odontología 07/03/2017   D4 B814 011685 07/03/2017 07/03/2017 Tesis de Doctorado




Horario de atención: Lunes a Viernes de 8:30 a 15:00 Hs.
Teléfonos: 351-5353600 int.: 62196-62160.
WhatsApp: 351-6456965
Correo electrónico: biblioteca@odontologia.unc.edu.ar
Búsquedas bibliográficas: busquedasbiblio@gmail.com



Powered by Koha